ECG Cable with Leads
NIBP Adult Cuff with Hose
SPO2 Sensor
Power Cord
Includes ECG, NIBP, SPO2
The Passport V is Mindray’s latest addition to a long line of portable patient monitors designed to meet the needs of caregivers in a range of clinical areas. Passport V is built on a solid foundation of experience and knowledge. It follows a proven approach to acquisition and presentation of patient data, thereby delivering impressive reliability and performance. Like other products in its line, the Passport V utilizes a straightforward, familiar interface so that the user’s experience is a positive one. It delivers just the right combination of simplicity and sophistication, offering a comprehensive feature-set in an uncomplicated, easy-to-learn manner.
Beyond that, this clever new monitor delivers just as much flexibility as you’ve come to rely on with our other patient monitors. The Passport V is available in a variety of versions, depending on your capability and technology preferences. With a broad range of options, it is well-suited for most hospital departments.
Enhanced capability, more optional features and extraordinary value make the Passport V a compelling alternative for any healthcare environment requiring continuous physiological monitoring.
MINDRAY DATASCOPE PASSPORT V SPECIFICATIONS
DISPLAY
Display Type: Color, anti-glare TFT display.
Size: 12.1" (246 x 184.4 mm.)
Resolution: SVGA 800 × 600 pixels.
Waveforms: 3 to 8.
ECG ( 3 AND 5-LEAD)
Leads: I, II, III, aVR, aVL, aVF, and V.
Cable Detection: Automatic Detection of 3 or 5-lead Sets.
Display Sensitivity: 1.25, 2.5, 5, 10, 20, 40 mm/mV.
ECG Signal Range: +/- 8 mV (peak-to-peak value.)
Calibration Signal: 1 mV (peak-to-peak value.)
FREQUENCY RESPONSE TO SCREEN
Surgical Mode: From 1 to 20 Hz.
Monitor Mode: From 0.5 to 40 Hz.
ST Mode: From 0.05 to 40 Hz.
Diagnostic Mode: From 0.05 to 150 Hz.
Defibrillation Protection: Withstand 360 Joule discharged current as per IEC 60601-2-27, 51.101.1.
Baseline Recovery Time: <5 s after defibrillation (in monitor and surgical mode.)
Defib. Synchronous Pulse: The time interval between the peaks of R-waves to the start of synchronous pulses is ≤35 ms.
ECG ANALOG OUTPUT
Delay: 25 ms max.
Sensitivity: 1 V/mV of input ±10%.
HEART RATE
Range: 15–300 bpm adult, 15–350 bpm pediatric, 15–350 bpm neonatal.
Accuracy: ±3 bpm or 3% at 30–250 bpm whichever is greater ±5% at 251–350 bpm, the greater of.
Pacer Pulse Rejection: Rejects pulses of amplitude between ±2 mV to ±700 mV and duration 0.1 ms to 2 ms with no tail.
Tall T Waves Rejection: Rejects all T-Waves of amplitude less than 1.2 mV, QRS 100 ms, QT interval of 350 ms, duration 180 ms.