No Shipping Fees Worldwide on $50+ Orders • SHOP NOW
Scican Statim 2000 G4 Autoclave Sterilizer - Fast Steam Sterilization for Dental & Medical Equipment | Perfect for Clinics, Hospitals & Laboratories
Scican Statim 2000 G4 Autoclave Sterilizer - Fast Steam Sterilization for Dental & Medical Equipment | Perfect for Clinics, Hospitals & Laboratories
Scican Statim 2000 G4 Autoclave Sterilizer - Fast Steam Sterilization for Dental & Medical Equipment | Perfect for Clinics, Hospitals & Laboratories
Scican Statim 2000 G4 Autoclave Sterilizer - Fast Steam Sterilization for Dental & Medical Equipment | Perfect for Clinics, Hospitals & Laboratories
Scican Statim 2000 G4 Autoclave Sterilizer - Fast Steam Sterilization for Dental & Medical Equipment | Perfect for Clinics, Hospitals & Laboratories

Scican Statim 2000 G4 Autoclave Sterilizer - Fast Steam Sterilization for Dental & Medical Equipment | Perfect for Clinics, Hospitals & Laboratories

$3847.25 $6995 -45% OFF

Free shipping on all orders over $50

7-15 days international

14 people viewing this product right now!

30-day free returns

Secure checkout

16431963

Guranteed safe checkout
amex
paypal
discover
mastercard
visa
apple pay

Description

BRAND NEW 1 Year Warranty

CycleSterilization Temp.Sterilization TimeTotal Cycle Time
(*does not include drying)
STATIM 2000 G4
Unwrapped135°C3.5 Minutes6 Minutes
Wrapped135°C10 Minutes14 Minutes
Rubber/Plastic121°C15 Minutes20 Minutes
Heavy Duty Unwrapped
/Air Drying
Air drying onlyAir drying onlyAir drying only
STATIM 5000 G4
Unwrapped132°C3.5 Minutes9 Minutes
Wrapped132°C6 Minutes17.5 Minutes
Rubber/Plastic121°C35 Minutes45 Minutes
Heavy Duty Unwrapped
/Air Drying
132°C6 Minutes12 Minutes

 

STATIM 2000 G4
Unit Size (L x W x H)19.5” x 16.3” x 5.9” or 49.5 cm x 41.5cm x 15cm
Cassette Internal Dimensions11” x 7.1” x 1.4” or 28cm x 18cm x 3.5cm
Weight Without Water46lbs or 21kg
Power Consumption110V, 60Hz, 11A

Benefits of the G4 network:

  • Monitoring real-time cycle data
  • Instant data logging
  • Proactive maintenance management
  • Automatic system updates to your G4 machines

FAST.

STATIM‘s unmatched speed and dependability have made STATIM the world’s best-selling autoclave. And its patented gentle technology has made STATIM the world’s favorite.

FORWARD.

The STATIM G4 will offer you a level of interactivity never seen before. The STATIM G4, through its LCD touch screen control and STATIM Live networking capability, has been designed to provide you with unprecedented ease of use and puts the user in total control.

DOCTORS AROUND THE WORLD RELY ON STATIM.

Healthcare practitioners in over 90 countries around the world rely on STATIM to protect their patients and staff from infection – with sterilized instruments in just minutes. In 1989, SciCan transformed the industry, developing the world’s first compact sterilization unit designed to meet the growing need for handpiece sterilization. Today, the STATIM still boasts superior cycle times and processes for both wrapped and unwrapped cycles. In fact, the STATIM Cassette Autoclave® sterilizes up to ten times faster than traditional ‘chamber style’ units. Employing a proprietary positive pressure pulse displacement technology – using saturated steam to remove air and effectively sterilize instruments between patients – the STATIM Autoclave ensures dentists always have an ample supply of instruments ready for use.

STATIM‘S SPEED

Reduces Instrument Investment

STATIM sterilizes handpieces and instruments for immediate use in as little as 8 minutes, reducing the number required as instruments can be processed ‘just in time’ or between patients.

Increases Efficiency

Fast point-of-use sterilization makes turnaround a priority, increasing efficiency and virtually eliminates instrument bottlenecks.

Gentle on Instruments

Our state-of-the-art steam technology is gentle on both solid and hollow instruments.

THE STATIM DIFFERENCE.

Immediate Steam Generation

Unlike conventional autoclaves that need to heat an entire reservoir of water, STATIM uses only a small, specific amount of water required for each cycle. Water is introduced into a heating device referred to as a ‘steam generator’, rapidly heated and converted to steam in mere seconds.

Air Removal

Using PPPD technology and our patented steam injection process – air is automatically forced out of the sterilization chamber.

Cassette System

The thin stainless steel walls of STATIM’s fully-removable cassette, (or sterilization chamber) allow for rapid heating and cooling of the chamber. As a result, STATIM meets the conditions for sterilization and drying in a fraction of the time required by a conventional autoclave.

Drying Technology

The STATIM 2000 and 5000 have each been designed to provide you with a complete solution: rapid sterilization balanced by rapid drying.

TOUCH. CONNECT. PROTECT. COLLECT.

Touch

A large 3.5” high-resolution touchscreen offers a vivid display of messages, current cycle information and customizable colours all with extraordinary clarity. Fully adjustable contrast levels let you optimize the screen to the lighting in your steri-centre.

Connect

Through your networked portal, you can view not only your STATIMs current operations in real time, you can also access cycle history, printing and validation information, and also sterilization records. Capable of sending emails with cycle information errors directly to your dealer, your STATIM G4 will let qualified technicians know when service is imminent.

Protect

Patient safety relies on attention to detail. The STATIM G4 supports verifiable processes that are PIN protected with user-defined IDs so that staff members can be required to authorize a cycle. This encourages extra attention to process and creates a safer environment for both staff and patients.

Collect

An undocumented sterilization cycle might as well not have been performed. With each cycle, information must be stored to protect your office and your patient. The integrated DataLogger stores all cycle information for the lifetime of the unit, which is accessible through multiple channels such as: a USB port for manual retrieval; an Ethernet connection for web based archiving or desktop printing; or a RS232 port for an external printer option.